[Cluster-devel] cluster/rgmanager/src/resources clusterfs.sh
lhh at sourceware.org
lhh at sourceware.org
Tue Nov 13 17:38:02 UTC 2007
CVSROOT: /cvs/cluster
Module name: cluster
Branch: RHEL5
Changes by: lhh at sourceware.org 2007-11-13 17:38:02
Modified files:
rgmanager/src/resources: clusterfs.sh
Log message:
Add self_fence support to RHEL5 branch for clusterfs
Patches:
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/rgmanager/src/resources/clusterfs.sh.diff?cvsroot=cluster&only_with_tag=RHEL5&r1=1.15.2.2&r2=1.15.2.3
--- cluster/rgmanager/src/resources/clusterfs.sh 2007/05/21 15:57:29 1.15.2.2
+++ cluster/rgmanager/src/resources/clusterfs.sh 2007/11/13 17:38:02 1.15.2.3
@@ -133,6 +133,18 @@
<content type="string"/>
</parameter>
+ <parameter name="self_fence">
+ <longdesc lang="en">
+ If set and unmounting the file system fails, the node will
+ immediately reboot. Generally, this is used in conjunction
+ with force-unmount support, but it is not required.
+ </longdesc>
+ <shortdesc lang="en">
+ Seppuku Unmount
+ </shortdesc>
+ <content type="boolean"/>
+ </parameter>
+
<parameter name="fsid">
<longdesc lang="en">
File system ID for NFS exports. This can be overridden
@@ -795,6 +807,15 @@
esac
fi
+ if [ -n "$mp" ]; then
+ case ${OCF_RESKEY_self_fence} in
+ $YES_STR) self_fence=$YES ;;
+ 1) self_fence=$YES ;;
+ *) self_fence="" ;;
+ esac
+ fi
+
+
#
# Always do this hackery on clustered file systems.
#
@@ -870,8 +891,13 @@
done # while
if [ -n "$umount_failed" ]; then
- ocf_log err "'umount $dev' failed ($mp), error=$ret_val"
+ ocf_log err "'umount $mp' failed, error=$ret_val"
+ if [ "$self_fence" ]; then
+ ocf_log alert "umount failed - REBOOTING"
+ sync
+ reboot -fn
+ fi
return $FAIL
fi
More information about the Cluster-devel
mailing list