<div>I got the following errors after "reboot -fn" on erd-tt-eproof1, which script do I need to change?</div>
<div> </div>
<div>Aug  9 15:35:40 erd-tt-eproof2 kernel: CMAN: removing node erd-tt-eproof1 from t<br>he cluster : Missed too many heartbeats<br>Aug  9 15:35:40 erd-tt-eproof2 fenced[3437]: erd-tt-eproof1 not a cluster member<br> after 0 sec post_fail_delay
<br>Aug  9 15:35:40 erd-tt-eproof2 fenced[3437]: fencing node "erd-tt-eproof1"<br>Aug  9 15:35:42 erd-tt-eproof2 fenced[3437]: agent "fence_drac" reports: WARNING<br>: unable to detect DRAC version ' Dell Embedded Remote Access Controller (ERA) F
<br>irmware Version 3.31 (Build 07.15) ' WARNING: unsupported DRAC version '__unknow<br>n__' failed: unable to determine power state<br><br>This is DRAC on Dell PE2650.</div>
<div>Thanks,</div>
<div>Hai<br> </div>
<div><span class="gmail_quote">On 8/9/06, <b class="gmail_sendername">Lon Hohberger</b> <<a href="mailto:lhh@redhat.com">lhh@redhat.com</a>> wrote:</span>
<blockquote class="gmail_quote" style="PADDING-LEFT: 1ex; MARGIN: 0px 0px 0px 0.8ex; BORDER-LEFT: #ccc 1px solid">On Wed, 2006-08-09 at 13:44 -0500, hai wu wrote:<br>> Thanks Lon. We got redundant power here.<br>><br>
> How can I test this fence_drac? How to simulate a failure on one node<br>> and know for sure that it does kick in and restarts the failed node in<br>> the cluster?<br><br>After both nodes join the cluster, try doing 'reboot -fn' on the node.
<br><br>Oh, also, you should be booting with acpi=off when using integrated<br>power management.<br><br>-- Lon<br><br><br><br>--<br>Linux-cluster mailing list<br><a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com