<div>Hi Celso,</div>
<div>I have one PV220S for test right now. Where can I set up the data transfer rate to 160 MB/s instead of 320 MB/s?</div>
<div>Thanks,</div>
<div>Hai<br><br> </div>
<div><span class="gmail_quote">On 8/15/06, <b class="gmail_sendername">Celso K. Webber</b> <<a href="mailto:celso@webbertek.com.br">celso@webbertek.com.br</a>> wrote:</span>
<blockquote class="gmail_quote" style="PADDING-LEFT: 1ex; MARGIN: 0px 0px 0px 0.8ex; BORDER-LEFT: #ccc 1px solid">Hello Brendan,<br><br>Although Dell hardware is an excellent choice for Linux, the PV220S<br>solution is terrible at performance under a cluster environment.
<br><br>The reason is that the PV220S itself does not manage RAID devices, it is<br>in fact a JBOD (Just a Bunch Of Disks). The RAID management is done by<br>the SCSI controllers within the servers (PERC 3/DC or PERC 4/DC).
<br><br>Since there is a possibility of one of the machines going down, together<br>with data in the controller's write cache, this solution automatically<br>disable the write cache (write through mode) when you set the<br>
controllers in "cluster mode".<br><br>The end result is very poor performance, specially on write operations.<br>It's not uncommon that Dell provides the PV-220S with 15K RPM disks to<br>compensate this performance penalty due to lack of write cache.
<br><br>As far as I can tell, Red Hat did support the PV220S solution in the<br>past, during the RHEL 2.1 era, but it is not supported anymore as<br>certified shared storage for cluster solutions (RHCS or RHGFS).<br><br>If you still plan to go on, be warned that the PV220S performs better in
<br>Cluster Mode if you set up the data transfer rate to 160 MB/s instead of<br>320 MB/s (the PERC 3/DC supports transfer rates of up to 160 MB/s while<br>the PERC 4/DC supports up to 320 MB/s). This is a known issue at Dell
<br>support queues.<br><br>As an extra information, there were too many problems about reliability<br>with the PV220S when used in Cluster Mode, this can be seen by the large<br>amount of firmware updates for the PERC 3/DC and 4/DC (LSI Logic based
<br>chipset, megaraid driver on Linux). More recent firmware versions seem<br>to have corrected most logical drive corruption problems I've<br>experienced, so I believe the PV220S is still worth a try if you can<br>live with the poor performance issue.
<br><br>Maybe a Dell|EMC AX-100 using iSCSI could a better choice with a not so<br>high price tag.<br><br>Sorry for the long message, I believe this information can be useful to<br>others.<br><br>Best regards,<br><br>Celso.
<br><br>Brendan Heading escreveu:<br>> Hi all,<br>><br>> I'm planning to build a cluster using a pair of PE1950s, using RHEL 3<br>> (or 4) with RHCS. Plan at the moment is to use GFS. Most of our stuff is<br>> Dell, therefore the obvious choice is to use a Dell PowerVault 220S as
<br>> the shared storage device.<br>><br>> Before I kick off with this idea I'd be interested to hear if anyone had<br>> any issues with this kind of setup, or if there were any general<br>> performance problems. Are there other SCSI enclosures which might be
<br>> better or more appropriate for these purposes ?<br>><br>> Regards<br>><br>> Brendan<br>><br>> --<br>> Linux-cluster mailing list<br>> <a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com
</a><br>> <a href="https://www.redhat.com/mailman/listinfo/linux-cluster">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br>><br><br>--<br>*Celso Kopp Webber*<br><br><a href="mailto:celso@webbertek.com.br">
celso@webbertek.com.br</a> <mailto:<a href="mailto:celso@webbertek.com.br">celso@webbertek.com.br</a>><br><br>*Webbertek - Opensource Knowledge*<br>(41) 8813-1919<br>(41) 3284-3035<br><br>--<br>Linux-cluster mailing list
<br><a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com</a><br><a href="https://www.redhat.com/mailman/listinfo/linux-cluster">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br></blockquote></div>
<br>