Hello all, <br><br>I´m configuring a 2 nodes cluster on 2 servers HP Proliant DL165 G5<br>This servers have HP ProLiant Lights-Out 100 Remote Management and I want to use it as fencing device.<br><br>My first idea was to configure them with IPMI and it works almost fine but I have detected that when I have the network down, the fence devices doesn't work because the nodes can't reach the othe node to fence it.<br>
<br>I have tried with a dedicated switch and a direct cable but it doesn't work and I begin to think I´m doing something wrong because the interface with the ipmi configured doesnt appear on the servers. I´ll try to explain:<br>
<br>I have<br>node1<br>eth0: IP1<br>eth1: IP2<br>In the bios I have configured ethMng : IP3<br><br>node2<br>
eth0: IP4<br>
eth1: IP5<br>
In the bios I have configured ethMng : IP6<br>
<br><br>with the network up all works fine and I can use fence_node to fence the nodes, and the cluster works fine.<br><br>But, if I disconnect IP1, IP2, IP3, IP4 (This simulate a switch fail) I expect the cluster become fencing with IP3 and IP6 but the system doesn't find these IP´s and all the cluster hungs. <br>
<br>Looking the fence devices avaliable with conga I have seen that there is one called:<br><table><tbody><tr><td><strong class="cluster"></strong><br></td>
                                <td>HP iLO</td></tr></tbody></table>with this parameters to configure:<br>Name      <br>Hostname     <br>Login     <br>Password     <br>Password Script (optional)<br><br>All are self explanatory but I don´t know what to put on Hostname (which hostname? the same machine, the other? FQDN.. IP....)<br>
<br>So, I have 2 questions:<br>If I use IPMI what I´m doing wrong?<br>and <br>If I use HP iLO, what I need to configure???<br><br>any idea, manual, doc, suggest.... is welcome<br><br>thanks in advance<br><br>ESG<br><br><br>