Hi, <div><br></div><div>I couldn´t reboot my system yet but I have installed the openmanage packages:</div><div><br></div><div><div>srvadmin-omacore-5.4.0-260</div><div>srvadmin-iws-5.4.0-260</div><div>srvadmin-syscheck-5.4.0-260</div>
<div>srvadmin-rac5-components-5.4.0-260</div><div>srvadmin-deng-5.4.0-260</div><div>srvadmin-ipmi-5.4.0-260.DUP</div><div>srvadmin-racadm5-5.4.0-260</div><div>srvadmin-omauth-5.4.0-260.rhel5</div><div>srvadmin-hapi-5.4.0-260</div>
<div>srvadmin-cm-5.4.0-260</div><div>srvadmin-racdrsc5-5.4.0-260</div><div>srvadmin-omilcore-5.4.0-260</div><div>srvadmin-isvc-5.4.0-260</div><div>srvadmin-storage-5.4.0-260</div><div>srvadmin-jre-5.4.0-260</div><div>srvadmin-omhip-5.4.0-260</div>
<div><br></div><div>Now I have the command racadm but when I try to execut it I get this:</div><div><br></div><div><div>racadm config -g cfgSerial -o cfgSerialTelnetEnable 1</div><div>ERROR: RACADM is unable to process the requested subcommand because there is no</div>
<div>local RAC configuration to communicate with.</div><div><br></div><div>Local RACADM subcommand execution requires the following:</div><div><br></div><div> 1. A Remote Access Controller (RAC) must be present on the managed server</div>
<div> 2. Appropriate managed node software must be installed and running on the</div><div>    server</div><div><br></div><div><br></div><div>What do I need to install/start? or until I configure the bios I can´t get this work?</div>
<div><br></div><div>Greetings</div><div><br></div><div>ESG</div></div></div><div><br><br><div class="gmail_quote">2009/8/11  <span dir="ltr"><<a href="mailto:bergman@merctech.com">bergman@merctech.com</a>></span><br>
<blockquote class="gmail_quote" style="margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left:1ex;"><br>
<br>
In the message dated: Tue, 11 Aug 2009 14:14:03 +0200,<br>
The pithy ruminations from Juan Ramon Martin Blanco on<br>
<Re: [Linux-cluster] do I have a fence DRAC device?> were:<br>
=> --===============1917368601==<br>
=> Content-Type: multipart/alternative; boundary=0016364c7c07663f600470dca3b8<br>
=><br>
=> --0016364c7c07663f600470dca3b8<br>
=> Content-Type: text/plain; charset=ISO-8859-1<br>
=> Content-Transfer-Encoding: quoted-printable<br>
=><br>
<div class="im">=> On Tue, Aug 11, 2009 at 2:03 PM, ESGLinux <<a href="mailto:esggrupos@gmail.com">esggrupos@gmail.com</a>> wrote:<br>
=><br>
=> > Thanks<br>
</div>=> > I=B4ll check it when I could reboot the server.<br>
<div class="im">=> ><br>
=> > greetings,<br>
=> ><br>
=> You have a BMC ipmi in the first network interface, it can be configured at<br>
=> boot time (I don't  remember if inside the BIOS or pressing cntrl+something<br>
=> during boot)<br>
</div>=><br>
<br>
Based on my notes, here's how I configured the DRAC interface on a Dell 1950<br>
for use as a fence device:<br>
<br>
        Configuring the card from Linux depending on the installation of Dell's<br>
        OMSA package. Once that's installed, use the following<br>
commands:<br>
<br>
                racadm config -g cfgSerial -o cfgSerialTelnetEnable 1<br>
                racadm config -g cfgLanNetworking -o cfgDNSRacName HOSTNAME_FOR_INTERFACE<br>
                racadm config -g cfgDNSDomainName DOMAINNAME_FOR_INTERFACE<br>
                racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 2 PASSWORD<br>
                racadm config -g cfgNicEnable 1<br>
                racadm config -g cfgNicIpAddress WWW.XXX.YYY.ZZZ<br>
                racadm config -g cfgNicNetmask WWW.XXX.YYY.ZZZ<br>
                racadm config -g cfgNicGateway WWW.XXX.YYY.ZZZ<br>
                racadm config -g cfgNicUseDhcp 0<br>
<br>
<br>
        I also save a backup of the configuration with:<br>
<br>
                racadm getconfig -f ~/drac_config<br>
<br>
<br>
Hope this helps,<br>
<br>
Mark<br>
<br>
----<br>
Mark Bergman                              voice: 215-662-7310<br>
<a href="mailto:mark.bergman@uphs.upenn.edu">mark.bergman@uphs.upenn.edu</a>                 fax: 215-614-0266<br>
System Administrator     Section of Biomedical Image Analysis<br>
Department of Radiology            University of Pennsylvania<br>
      PGP Key: <a href="https://www.rad.upenn.edu/sbia/bergman" target="_blank">https://www.rad.upenn.edu/sbia/bergman</a><br>
<br>
<br>
=> Greetings,<br>
<div><div></div><div class="h5">=> Juanra<br>
=><br>
=> ><br>
=> > ESG<br>
=> ><br>
=> > 2009/8/10 Paras pradhan <<a href="mailto:pradhanparas@gmail.com">pradhanparas@gmail.com</a>><br>
=> ><br>
=> > On Mon, Aug 10, 2009 at 5:24 AM, ESGLinux<<a href="mailto:esggrupos@gmail.com">esggrupos@gmail.com</a>> wrote:<br>
=> >> > Hi all,<br>
=> >> > I was designing a 2 node cluster and I was going to use 2 servers DELL<br>
=> >> > PowerEdge 1950. I was going to buy a DRAC card to use for fencing but<br>
=> >> > running several commands in the servers I have noticed that when I run<br>
=> >> this<br>
=> >> > command:<br>
=> >> > #ipmitool lan print<br>
=> >> > Set in Progress : Set Complete<br>
=> >> > Auth Type Support : NONE MD2 MD5 PASSWORD<br>
=> >> > Auth Type Enable : Callback : MD2 MD5<br>
=> >> >                         : User : MD2 MD5<br>
=> >> >                         : Operator : MD2 MD5<br>
=> >> >                         : Admin : MD2 MD5<br>
=> >> >                         : OEM : MD2 MD5<br>
=> >> > IP Address Source : Static Address<br>
=> >> > IP Address : 0.0.0.0<br>
=> >> > Subnet Mask : 0.0.0.0<br>
=> >> > MAC Address : 00:1e:c9:ae:6f:7e<br>
=> >> > SNMP Community String : public<br>
=> >> > IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10<br>
=> >> > Default Gateway IP : 0.0.0.0<br>
=> >> > Default Gateway MAC : 00:00:00:00:00:00<br>
=> >> > Backup Gateway IP : 0.0.0.0<br>
=> >> > Backup Gateway MAC : 00:00:00:00:00:00<br>
=> >> > 802.1q VLAN ID : Disabled<br>
=> >> > 802.1q VLAN Priority : 0<br>
=> >> > RMCP+ Cipher Suites : 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14<br>
=> >> > Cipher Suite Priv Max : aaaaaaaaaaaaaaa<br>
=> >> >                         : X=Cipher Suite Unused<br>
=> >> >                         : c=CALLBACK<br>
=> >> >                         : u=USER<br>
=> >> >                         : o=OPERATOR<br>
=> >> >                         : a=ADMIN<br>
=> >> >                         : O=OEM<br>
=> >> > does this mean that I already have an ipmi card (not configured) that<br>
=> I<br>
=> >> can<br>
=> >> > use for fencing? if the anwser is yes, where hell must I configure it?<br>
=>  I<br>
</div></div>=> >> > don=B4t see wher can I do it.<br>
=> >> > If I haven=B4t a fencing device which one do you recommed to use?<br>
<div><div></div><div class="h5">=> >> > Thanks in advance<br>
=> >> > ESG<br>
=> >> ><br>
=> >> > --<br>
=> >> > Linux-cluster mailing list<br>
=> >> > <a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com</a><br>
=> >> > <a href="https://www.redhat.com/mailman/listinfo/linux-cluster" target="_blank">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br>
=> >> ><br>
=> >><br>
=> >> Yes you have IPMI and if you are using 1950 Dell, DRAC should be there<br>
=> >> too. You can see if you have DRAC or not when the server starts and<br>
=> >> before the loading of the OS.<br>
=> >><br>
=> >> I have 1850s and I am using DRAC for fencing.<br>
=> >><br>
=> >><br>
=> >> Paras.<br>
=> >><br>
=> >> --<br>
=> >> Linux-cluster mailing list<br>
=> >> <a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com</a><br>
=> >> <a href="https://www.redhat.com/mailman/listinfo/linux-cluster" target="_blank">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br>
=> >><br>
=> ><br>
=> ><br>
<br>
<br>
<br>
--<br>
Linux-cluster mailing list<br>
<a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com</a><br>
<a href="https://www.redhat.com/mailman/listinfo/linux-cluster" target="_blank">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br>