<div dir="ltr"><div>Hi.</div>
<div> </div>
<div>I got 2 power supplies. But if someone by mistake pull the power cables , is that mean</div>
<div> </div>
<div>That the services will not failover ??</div>
<div> </div>
<div>Regards</div>
<div> </div>
<div>Shalom.<br><br></div>
<div class="gmail_quote">On Wed, Mar 3, 2010 at 1:15 AM, Georgi Stanojevski <span dir="ltr"><<a href="mailto:glisha@gmail.com">glisha@gmail.com</a>></span> wrote:<br>
<blockquote class="gmail_quote" style="PADDING-LEFT: 1ex; MARGIN: 0px 0px 0px 0.8ex; BORDER-LEFT: #ccc 1px solid">
<div class="im">
<div class="gmail_quote">On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <span dir="ltr"><<a href="mailto:sklemer@gmail.com" target="_blank">sklemer@gmail.com</a>></span> wrote:<br>  
<blockquote class="gmail_quote" style="PADDING-LEFT: 1ex; MARGIN: 0pt 0pt 0pt 0.8ex; BORDER-LEFT: rgb(204,204,204) 1px solid">
<div dir="ltr">
<div>
<div dir="ltr">
<div><font face="Arial" size="2"><span>The only test which failed was - pulling out power cable from one node.</span></font></div>
<div><font face="Arial" size="2"><span></span></font> </div>
<div><font face="Arial" size="2"><span>The other system try in loop fencing the failed node & services not relocated.</span></font></div>
<div><font face="Arial" size="2"><span></span></font> </div><br></div></div></div></blockquote></div><br></div>As I understand this is by design.<br><br>When you pull out the power cables you shutdown the fencing device on that node and the remaining node can't successfully fence it.<br>
<br>The nodes should have redundant power supplies, to avoid single point of failure.<br><font color="#888888"><br>-- <br>Glisha<br>http://<br></font><br>--<br>Linux-cluster mailing list<br><a href="mailto:Linux-cluster@redhat.com">Linux-cluster@redhat.com</a><br>
<a href="https://www.redhat.com/mailman/listinfo/linux-cluster" target="_blank">https://www.redhat.com/mailman/listinfo/linux-cluster</a><br></blockquote></div><br></div>