Well, after reading man openais.conf the settings below seemed ok for this operation, so I just went ahead with it. I connected the old and new switch and moved the cluster nodes over one by one (which meant the link was down for 4-5 seconds). There were no problems whatsoever.<div>
<br></div><div>Cheers,</div><div>Martijn<br><br><div class="gmail_quote">On Fri, Jun 17, 2011 at 9:26 AM, Martijn Storck <span dir="ltr"><<a href="mailto:martijn.storck@gmail.com">martijn.storck@gmail.com</a>></span> wrote:<br>
<blockquote class="gmail_quote" style="margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left:1ex;">Hi all,<div><br></div><div>Unfortunately I have to swap out the switch that is used for the cluster traffic of our 4-node cluster for a new one. I'm hoping I can do this by connecting the new switch to the old switch and then moving the nodes over one by one.</div>

<div><br></div><div>Can I change the cluster configuration so that there is a longer grace period before a node is deemed 'lost' and gets fenced? The only line in my cluster.conf that looks like it has anything to do with it is this one:</div>

<div><br></div><div>        <totem consensus="4800" join="60" token="10000" token_retransmits_before_loss_const="20"/></div><div><br></div><div>I think that with faststart enabled the link with a node will be down for only a few seconds. I realize that this probably means the cluster will lock up during that period (since we use a lot of GFS), but it's still better than having to bring the entire cluster down.</div>

<div><br></div><div>Kind regards,</div><div>Martijn Storck</div>
</blockquote></div><br></div>