<div dir="ltr">I contacted DELL and was told it was normal because it was idrac6 Express and it use a shared LOM for OS and idrac.<div><br></div><div>I've rebooted manually the servers and lost connectivity with idrac for 120 seconds aprox.</div>

<div><br></div><div>The weird thing is fence_ipmilan works from a centos 6.4 server.<br><div><br></div><div>We have some others Hp servers with iLo and when I restart the server I lost connection with ilo while booting</div>

</div></div><div class="gmail_extra"><br><br><div class="gmail_quote">On Wed, Feb 19, 2014 at 8:05 PM, Pavel Herrmann <span dir="ltr"><<a href="mailto:morpheus.ibis@gmail.com" target="_blank">morpheus.ibis@gmail.com</a>></span> wrote:<br>

<blockquote class="gmail_quote" style="margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left:1ex">Hello,<br>
<div class=""><br>
On Wednesday 19 of February 2014 19:30:52 Michael Mendoza wrote:<br>
> Good afternoon.<br>
><br>
> We are trying to configure 2 dell R610 with idrac6 EXPRESS in cluster with<br>
> redhat 5.10 x64.<br>
><br>
> For testing we are using the command fence_ipmilan. We can ping idrac on<br>
> the remote host.<br>
><br>
> fence_ipmilan -a X.X.X.X -l usern -p xxxx  -t 200  -o status  -v   <-- works<br>
><br>
><br>
> fence_ipmilan -a X.X.X.X -l usern -p xxxx  -t 200  -o reboot -v<br>
><br>
> The problem is the server reboot, but while it reboot the idrac6 reboot<br>
> too. so the host A after 120 seconds aprox lost connection and get the<br>
> follow message.<br>
<br>
</div>This seems wrong, when doing a system reboot through IPMI, your BMC should not<br>
reboot. does this happen if you use ipmitool or similar tool to reboot the<br>
machine?<br>
<div class="HOEnZb"><div class="h5"><br>
<br>
><br>
> > Spawning: '/usr/bin/ipmitool -I lan -H 'X.X.X.X' -U 'usern' -P '[set]' -v<br>
> > -v -v chassis power on'...<br>
> > Spawned: '/usr/bin/ipmitool -I lan -H 'X.X.X.X' -U 'usern' -P '[set]' -v<br>
> > -v -v chassis power on' - PID 10104<br>
> > Looking for:<br>
> > 'Password:', val = 1<br>
> > 'Unable to establish LAN', val = 11<br>
> > 'IPMI mutex', val = 14<br>
> > 'Unsupported cipher suite ID', val = 2048<br>
> > 'read_rakp2_message: no support for', val = 2048<br>
> > 'Up/On', val = 0<br>
> > ExpectToken returned 11<br>
> > Reaping pid 10104<br>
> > Failed<br>
><br>
> cman version is CMAN-2.0.115.118.e15_10.3<br>
><br>
><br>
> however I have other host with centos 6.4 and CMAN3.0... and the connection<br>
> is not lost. I run the same command, the server reboot as well as idrac,<br>
> the ping is back and the ipmi connection is not lost..<br>
><br>
>  am I doing something wrong? I used the -t and -T option even 300 / 400 and<br>
> it doesnt matter, the connection is shut after 120secounds. in centos work<br>
> fine. ( I already opened a case with redhat and am waiting answer.)<br>
> Thanks<br>
<br>
</div></div></blockquote></div><br><br clear="all"><div><br></div>-- <br>--Michael Mendoza--
</div>