[dm-devel] Problem with Multipath (devices not ready)

João Daniel jd-apinf at est.ips.pt
Tue Jan 31 17:38:48 UTC 2006


Hi,

 

 

 

I have upgraded from SLES9-SP2 to SLES9-SP3.

The purpose was to fix some problems related to OCFS2.

 

I have many warnings (as you can see below) in my /var/log/messages related
to multipath (i think), indicating that the devices aren't ready. 

Maybe the multipath.conf needs some extra configuration (please see my
multipath.conf).

The sdc and sdd devices are disks out on the EMC.

 

 

Can anyone help me with this problem ?

 

 

 

 

 

 

ERROR MESSAGES:

 

(...)

Jan 27 16:16:18 siipstestes kernel: Device sdc not ready.

Jan 27 16:16:18 siipstestes kernel: Device sdd not ready.

Jan 27 16:16:29 siipstestes kernel: Device sdc not ready.

Jan 27 16:16:29 siipstestes kernel: Device sdd not ready.

Jan 27 16:16:40 siipstestes kernel: Device sdc not ready.

Jan 27 16:16:40 siipstestes kernel: Device sdd not ready.

Jan 27 16:16:51 siipstestes kernel: Device sdc not ready.

Jan 27 16:16:51 siipstestes kernel: Device sdd not ready.

Jan 27 16:17:02 siipstestes kernel: Device sdc not ready.

Jan 27 16:17:02 siipstestes kernel: Device sdd not ready.

Jan 27 16:17:13 siipstestes kernel: Device sdc not ready.

Jan 27 16:17:13 siipstestes kernel: Device sdd not ready.

Jan 27 16:17:24 siipstestes kernel: Device sdc not ready.

Jan 27 16:17:24 siipstestes kernel: Device sdd not ready.

Jan 27 16:17:35 siipstestes kernel: Device sdc not ready.

Jan 27 16:17:35 siipstestes kernel: Device sdd not ready.

Jan 27 16:17:46 siipstestes kernel: Device sdc not ready.

Jan 27 16:17:46 siipstestes kernel: Device sdd not ready.

(...)

 

 

 

 

 

server:~ # multipath -v2 -l

dm names   N  

dm table LUN_TESTES  N  

dm table LUN_TESTES  N  

dm status LUN_TESTES  N  

dm info LUN_TESTES  O  

LUN_TESTES (360060160256014006adcbf64a644da11)

[size=458 GB][features="0"][hwhandler="0"]

\_ round-robin 0 [active]

 \_ 3:0:0:0 sdc 8:32 [failed][faulty]

 \_ 3:0:1:0 sdd 8:48 [failed][faulty]

 \_ 3:0:2:0 sde 8:64 [active][ready]

 \_ 3:0:3:0 sdf 8:80 [active][ready]

 

 

 

 

 

 

 

 

 

Here is my MULTIPATH.CONF file:

 

 

defaults {

            multipath_tool   "/sbin/multipath -v 0 -S"

            udev_dir            /dev

            polling_interval 10

            default_selector "round-robin 0"

    #default_path_grouping_policy           failover

            default_path_grouping_policy     multibus

            default_getuid_callout    "/sbin/scsi_id -g -u -s /block/%n"

            #default_prio_callout      "/bin/false"

    failback        immediate

}

 

#

# name    : devnode_blacklist

# scope   : multipath & multipathd

# desc    : list of device names to discard as not multipath candidates

# default : cciss, fd, hd, md, dm, sr, scd, st, ram, raw, loop

#

devnode_blacklist {

            devnode cciss

            devnode fd

            devnode hd

            devnode md

            devnode dm-

            devnode sr

            devnode scd

            devnode st

            devnode ram

            devnode raw

            devnode loop

            devnode sda

            devnode sdb

}

 

#

# name    : multipaths

# scope   : multipath & multipathd

# desc    : list of multipaths finest-grained settings

#

multipaths {

            #

            # name  : multipath

            # scope : multipath & multipathd

            # desc  : container for settings that apply to one specific
multipath

            #

            multipath {

                        wwid
360060160256014006adcbf64a644da11

                        alias                             LUN_TESTES

            }

}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HARDWARE:

 

- DELL 2850

- 1x QLogic 2340 (BIOS 1.47) to acess my Storage (EMC Clariion CX300)

 

 

 

 

SOFTWARE:

 

- SLES9 (32 bit) + SP3 (with Multipath and OCFS2 configured)

- Oracle Clusterware Release 2 (10.2.0.1.0)

- Oracle Database 10g Release 2 (10.2.0.1.0)

- Qlogic driver: qlafc-linux-8.01.00-4-install.tgz.gz

- Naviagent CLI: naviagentcli-6.16.0.4.63-1.i386.rpm

- SANsurfer: emc_sansurfer2.0.30b52_linux_install.bin

 

- Multipath 0.4.5-0.11

 

 

 

 

 

 

Best regards,

 

 

 

 





João Daniel




Apoio Informático 

Sistema de Informação do Instituto Politécnico de Setúbal 

 <mailto:jd-apinf at est.ips.pt> 

Instituto Politécnico de Setúbal 
Esc. Sup. de Tec. de Setúbal 

Campus do IPS, Estefanilha
2910-761 Setúbal 





tel:   


+351 265 790 133
+351 265 790 119

 

 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/dm-devel/attachments/20060131/53b39792/attachment.htm>


More information about the dm-devel mailing list