[dm-devel] Recent kernels fail to boot on POWER8 with multipath SCSI
Mike Snitzer
snitzer at redhat.com
Fri Mar 30 11:49:27 UTC 2018
On Fri, Mar 30 2018 at 5:04P -0400,
Michael Ellerman <michael at ellerman.id.au> wrote:
> Hi Mike,
>
> Paul's AFK so I tried the patch you sent.
>
> Mike Snitzer <snitzer at redhat.com> writes:
> > On Thu, Mar 29 2018 at 4:39am -0400,
> > Paul Mackerras <paulus at ozlabs.org> wrote:
> >> Since commit 8d47e65948dd ("dm mpath: remove unnecessary NVMe
> >> branching in favor of scsi_dh checks", 2018-03-05), upstream kernels
> >> fail to boot on my POWER8 box which has multipath SCSI disks. The
> >> host adapters are IPR and the userspace is CentOS 7.
> ...
> >
> > Please try this patch, it'll likely fix your issues:
> >
> > diff --git a/drivers/md/dm-mpath.c b/drivers/md/dm-mpath.c
> > index dbddcdc5a4ec..746dd8a75b4a 100644
> > --- a/drivers/md/dm-mpath.c
> > +++ b/drivers/md/dm-mpath.c
> > @@ -887,7 +887,7 @@ static struct pgpath *parse_path(struct dm_arg_set *as, struct path_selector *ps
> >
> > q = bdev_get_queue(p->path.dev->bdev);
> > attached_handler_name = scsi_dh_attached_handler_name(q, GFP_KERNEL);
> > - if (attached_handler_name) {
> > + if (attached_handler_name || m->hw_handler_name) {
> > INIT_DELAYED_WORK(&p->activate_path, activate_path_work);
> > r = setup_scsi_dh(p->path.dev->bdev, m, attached_handler_name, &ti->error);
> > if (r) {
>
> And it does indeed fix the problem. The system boots happily with no warnings.
Great, thanks for verifying.
> If you like here's a:
>
> Tested-by: Michael Ellerman <mpe at ellerman.id.au>
Already sent to Linus and included.
> Any prospect of getting that patch to Linus before the 4.16 release? Yes
> I realise that's in ~36 hours :)
Please, see upstream commit e457edf0b21c873be827b7c2f6b8e1545485c415
Thanks,
Mike