Hi Martin,
I have tested 0.7.7 and 0.8.5 code.They both have metadate error.
I find I missed some information in last email. Ip1 log in between (1)
and (2) and sdi became a path of 36001405b7679bd96b094bccbf971bc90, but
uevents weren't deal until (3) finished.
The details described are base on code 0.7.7. I think similar process
exists in 0.8.5 but there may be another to cause error.
The latest "queue" code isn't tested. I will try.
Regards,
Lixiaokeng
On 2021/1/19 17:41, Martin Wilck wrote:
> Hi Lixiaokeng,
>
> On Mon, 2021-01-18 at 19:08 +0800, lixiaokeng wrote:
>> Hi
>> When we make IO stress test on multipath device, there will
>> be a metadata err because of wrong path.
>>
>
> thanks for the detailed report and analysis, also for sharing
> your test scripts! I'll take a closer look asap. Meanwhile, please
> confirm which multipath-tools version you were using, and whether this
> occurs with the latest "queue" code:
>
> https://github.com/openSUSE/multipath-tools/tree/queue
>
> Regards
> Martin
>
>
> .
>