<div dir="ltr">Right,<div><br></div><div>so Xosé, can you confirm the last introduced hwtable entries don't need the alua hwhandler :</div><div>- nexsan</div><div>- tegile</div><div>- nimble</div><div>- nfinidat</div><div><br></div><div>Thanks.</div></div><div class="gmail_extra"><br><div class="gmail_quote">On Tue, Oct 11, 2016 at 8:22 AM, Hannes Reinecke <span dir="ltr"><<a href="mailto:hare@suse.de" target="_blank">hare@suse.de</a>></span> wrote:<br><blockquote class="gmail_quote" style="margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left:1ex"><span class="">On 10/11/2016 08:02 AM, Christophe Varoqui wrote:<br>
> I'm not comfortable with this patch that induces a less predictable<br>
> behaviour.<br>
> We have that retain hardware handler switch that users can activate to<br>
> achieve the purpose.<br>
><br>
> Hannes, Ben, would you support that patch ?<br>
><br>
> Best Regards,<br>
> Christophe<br>
><br>
</span>Please don't apply this.<br>
Autodetection will only work if the hardware handler is loaded.<br>
If the handler is _not_ loaded autodetection won't work, either.<br>
And if we add this patch multipath will never load the modules, neither.<br>
<br>
So we need this functionality as a fallback if autodetect does not work.<br>
<br>
Cheers,<br>
<br>
Hannes<br>
<span class="HOEnZb"><font color="#888888">--<br>
Dr. Hannes Reinecke Teamlead Storage & Networking<br>
<a href="mailto:hare@suse.de">hare@suse.de</a> <a href="tel:%2B49%20911%2074053%20688" value="+4991174053688">+49 911 74053 688</a><br>
SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg<br>
GF: F. Imendörffer, J. Smithard, J. Guild, D. Upmanyu, G. Norton<br>
HRB 21284 (AG Nürnberg)<br>