3ware RAID card oddity in 2.6.3-2.1.253smp x86_64
Charles Jones
jonescr at cisco.com
Fri Mar 12 02:46:00 UTC 2004
I have an Fedora x86_64 system with a 3ware Escalade 7506-12 card.
When I load the 3w-xxxx.ko module I get the following output:
---snip---
SCSI subsystem initialized
3ware Storage Controller device driver for Linux v1.02.00.037.
scsi0 : Found a 3ware Storage Controller at 0xac00, IRQ: 27, P-chip: 1.3
scsi0 : 3ware Storage Controller
Vendor: 3ware Model: Logical Disk 0 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 1 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 2 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 3 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 4 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 5 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 6 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
Vendor: 3ware Model: Logical Disk 7 Rev: 1.0
Type: Direct-Access ANSI SCSI revision: 00
-----
This is the same output I got with earlier kernels, except this time the
disks are not assigned to SCSI devices. Is this a known issue? I poked
around on Bugzilla and the only 3ware problems I see are in the 2.4
kernel, and I have no problems with the 2.4 kernel on a 32bit machine.
More information about the fedora-devel-list
mailing list