2 SCSI Controllers
Frank Warnke
frank at newspapersystems.com
Thu Apr 29 13:42:13 UTC 2004
Götz Reinicke wrote:
> Hi,
>
> I have an Dell PE 1650 Server with an internal perc 3/di SCSI RAID
> Controller hosting a RAID 1 and an Adaptec 29160 Controller hosting an
> external Hardware RAID-Box.
>
> If I boot, and try to install Fedora, the external RAID is seen as
sda,
> the internal RAID as sdb.
>
> How can I change this order, so that the internal RAID is sda and the
> external RAID is sdb? Any ideas?
>
>
> Regards
>
> Götz Reinicke
I had a similar problem on a Dell PE600SC and Red Hat v9.
In order for the Dell CERC (megaraid) device to be /dev/sda, I
had to set the an option in the CMOS;
Setup CMOS Hard-Disk Drive Sequence
1. System BIOS boot devices
2. Slot3: CERC ATA-100/4ch (bus 00 dev 05)
3. Slot5: 3ware Storage Controller
Moving the cards around and setting the above options did not make a
difference to what the POST saw. Linux, however, did notice a
difference when I configured the above CMOS options. By default, the
3ware card was being seen before the Megaraid by Linux.
Thanks,
Frank
More information about the fedora-list
mailing list