Errors

Michael Hart mixstat at bigpond.net.au
Thu Jul 29 10:17:13 UTC 2004


Thanks Charles,

Here are some outputs from smartctl.  It seems that hda has some raw 
read errors and hdc has some crc errors.  I do not know how significant 
these are.

I thought smart was designed to give an estimate until failure.

[root at Jupiter log]# smartctl -a /dev/hda
smartctl version 5.21 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     IC35L060AVER07-0
Serial Number:    SZ0SZLC3375
Firmware Version: ER6OA44A
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   5
ATA Standard is:  ATA/ATAPI-5 T13 1321D revision 1
Local Time is:    Thu Jul 29 20:10:13 2004 EST

==> WARNING: IBM Deskstar 60GXP drives may need upgraded SMART firmware.
Please see http://www.geocities.com/dtla_update/index.html#rel

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity was
                                         never started.
                                         Auto Offline Data Collection: 
Disabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                 (2042) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         No Conveyance Self-test supported.
                                         No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  34) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000b   095   095   060    Pre-fail 
Always       -       655366
   2 Throughput_Performance  0x0005   100   100   050    Pre-fail 
Offline      -       0
   3 Spin_Up_Time            0x0007   110   110   024    Pre-fail 
Always       -       284 (Average 305)
   4 Start_Stop_Count        0x0012   100   100   000    Old_age 
Always       -       303
   5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail 
Always       -       24
   7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail 
Always       -       0
   8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail 
Offline      -       0
   9 Power_On_Hours          0x0012   097   097   000    Old_age 
Always       -       24762
  10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age 
Always       -       281
192 Power-Off_Retract_Count 0x0032   100   100   050    Old_age   Always 
       -       303
193 Load_Cycle_Count        0x0012   100   100   050    Old_age   Always 
       -       303
194 Temperature_Celsius     0x0002   119   119   000    Old_age   Always 
       -       46 (Lifetime Min/Max 13/61)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always 
       -       50
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always 
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [Use the smartctl -t option to run these.]


[root at Jupiter log]# smartctl -a /dev/hdc
smartctl version 5.21 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD1600BB-00DWA0
Serial Number:    WD-WMAEK1692022
Firmware Version: 15.05R15
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   6
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Jul 29 20:10:47 2004 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity was
                                         suspended by an interrupting 
command from host.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                 (5061) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                         No Auto Offline data collection 
support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  67) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000b   200   200   051    Pre-fail 
Always       -       0
   3 Spin_Up_Time            0x0007   145   144   021    Pre-fail 
Always       -       3266
   4 Start_Stop_Count        0x0032   100   100   040    Old_age 
Always       -       73
   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x000b   100   253   051    Pre-fail 
Always       -       0
   9 Power_On_Hours          0x0032   098   098   000    Old_age 
Always       -       1497
  10 Spin_Retry_Count        0x0013   100   253   051    Pre-fail 
Always       -       0
  11 Calibration_Retry_Count 0x0013   100   253   051    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age 
Always       -       53
194 Temperature_Celsius     0x0022   108   253   000    Old_age   Always 
       -       42
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always 
       -       0
197 Current_Pending_Sector  0x0012   200   200   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0012   200   200   000    Old_age   Always 
       -       0
199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always 
       -       2692
200 Multi_Zone_Error_Rate   0x0009   200   155   051    Pre-fail 
Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [Use the smartctl -t option to run these.]


[root at Jupiter log]#

Charles Heselton wrote:
> I've seen errors like this on Sun systems when the disk is about to
> keel over.  I'd check you're hard drive and/or replace it.
> 
> On Thu, 29 Jul 2004 10:28:11 +1000, Michael Hart <mixstat at bigpond.net.au> wrote:
> 





More information about the fedora-list mailing list