Problem with SCSI drive order
Dan Haines
dan.haines at metservice.com
Fri May 28 03:45:22 UTC 2004
Hi list
I have a problem. (who doesnt, right?)
I have a cluster setup, high availability, using clumanager. I also
have external RAID configured on these two machines.
Originally, when I upgraded to FC2, the RAID came up as /dev/sda, and
the internal hdd came up as /dev/sdb. With that not being desirable, I
made a change to the initrd, using this command:
mkinitrd -f -v --preload=aic79xx /boot/initrd-2.6.5-1.358custom.img
2.6.5-1.358custom
The preloaded scsi driver, is the one controlling the internal drive.
This change, made the internal drive become /dev/sda again, and the RAID
/dev/sdb, like I want it.
Now, Ive just installed a 146gb SCSI disk into one of the servers, and
after a reboot (I could see no way to make FC2 pick up the SCSI drive
without rebooting) its picked up the 146gb new SCSI disk as /dev/sda,
moved the original internal SCSI disk to /dev/sdb, and moved the RAID to
/dev/sdc.
Preferably, I would like this:
/dev/sda = Internal SCSI disk
/dev/sdb = external RAID
/dev/sdc = the new SCSI disk ive just added
I need /dev/sdb to be the RAID, as Im using RAWDEVICES to allocate some
common drive space, for the cluster software to run. These RAWDEVICES
are /dev/sdb1 and /dev/sdb2 (on RAID)..
Please, can anyone offer me some assistance, or a way to force the new
SCSI disk ive just added, to become /dev/sdc?
TIA!!!!
Dan
More information about the fedora-list
mailing list