RAID 5 Multiple Hard-drives failure

Dan grinnz at gmail.com
Tue Mar 14 19:31:19 UTC 2006


Reuben D. Budiardja wrote:

>On Tuesday 14 March 2006 08:49, Scot L. Harris wrote:
>  
>
>>On Tue, 2006-03-14 at 08:21 -0500, Reuben D. Budiardja wrote:
>>    
>>
><snip>
>  
>
>>>I am hoping for comments, etc. Thank you in advance.
>>>      
>>>
>>Have you monitored the temperature of the system at all times?  Heat can
>>play a major roll in causing drives and other hardware to fail long
>>before it should.  Good air flow around the system/drives is critical.
>>    
>>
>
>I have not. Any recommended tools , methods ? Thank you.
>  
>
Install hddtemp, then have the hddtemp service start on startup 
(system-config-services, or appropriate tools). With the service 
starting, drive temperatures can be accessed through the command "telnet 
localhost 7634" or from remote machines (see man hddtemp). Or just use 
the "hddtemp /dev/sda /dev/sdb /dev/hda /dev/hdb" command, with the 
appropriate device names. You can also use gkrellm and the 
gkrellm-hddtemp plugin with the hddtemp service running to have a 
constant temperature display for all drives that hddtemp can recognize 
(it didn't work for any of my drives until a recent update, now I don't 
have any that it can't read).
-Dan




More information about the fedora-list mailing list