[libvirt] [PATCH v2 4/4] Allow choice of shutdown method via virsh

Michal Privoznik mprivozn at redhat.com
Mon Jan 23 14:48:04 UTC 2012


Extend the 'shutdown' and 'reboot' methods so that they both
accept a new argument

    --mode acpi|agent

* tools/virsh.c: New args for shutdown/reboot
* tools/virsh.pod: Document new args
---
 tools/virsh.c   |   47 +++++++++++++++++++++++++++++++++++++++++++++--
 tools/virsh.pod |   12 ++++++++++--
 2 files changed, 55 insertions(+), 4 deletions(-)

diff --git a/tools/virsh.c b/tools/virsh.c
index d635b56..5560988 100644
--- a/tools/virsh.c
+++ b/tools/virsh.c
@@ -3850,6 +3850,7 @@ static const vshCmdInfo info_shutdown[] = {
 
 static const vshCmdOptDef opts_shutdown[] = {
     {"domain", VSH_OT_DATA, VSH_OFLAG_REQ, N_("domain name, id or uuid")},
+    {"mode", VSH_OT_STRING, VSH_OFLAG_NONE, N_("shutdown mode: acpi|agent")},
     {NULL, 0, 0, NULL}
 };
 
@@ -3859,14 +3860,37 @@ cmdShutdown(vshControl *ctl, const vshCmd *cmd)
     virDomainPtr dom;
     bool ret = true;
     const char *name;
+    const char *mode = NULL;
+    int flags = 0;
+    int rv;
 
     if (!vshConnectionUsability(ctl, ctl->conn))
         return false;
 
+    if (vshCommandOptString(cmd, "mode", &mode) < 0) {
+        vshError(ctl, "%s", _("Invalid type"));
+        return false;
+    }
+
+    if (mode) {
+        if (STREQ(mode, "acpi")) {
+            flags |= VIR_DOMAIN_SHUTDOWN_ACPI_POWER_BTN;
+        } else if (STREQ(mode, "agent")) {
+            flags |= VIR_DOMAIN_SHUTDOWN_GUEST_AGENT;
+        } else {
+            vshError(ctl, _("Unknown mode %s value, expecting 'acpi' or 'agent'"), mode);
+            return false;
+        }
+    }
+
     if (!(dom = vshCommandOptDomain(ctl, cmd, &name)))
         return false;
 
-    if (virDomainShutdown(dom) == 0) {
+    if (flags)
+        rv = virDomainShutdownFlags(dom, flags);
+    else
+        rv = virDomainShutdown(dom);
+    if (rv == 0) {
         vshPrint(ctl, _("Domain %s is being shutdown\n"), name);
     } else {
         vshError(ctl, _("Failed to shutdown domain %s"), name);
@@ -3888,6 +3912,7 @@ static const vshCmdInfo info_reboot[] = {
 
 static const vshCmdOptDef opts_reboot[] = {
     {"domain", VSH_OT_DATA, VSH_OFLAG_REQ, N_("domain name, id or uuid")},
+    {"mode", VSH_OT_STRING, VSH_OFLAG_NONE, N_("shutdown mode: acpi|agent")},
     {NULL, 0, 0, NULL}
 };
 
@@ -3897,14 +3922,32 @@ cmdReboot(vshControl *ctl, const vshCmd *cmd)
     virDomainPtr dom;
     bool ret = true;
     const char *name;
+    const char *mode = NULL;
+    int flags = 0;
 
     if (!vshConnectionUsability(ctl, ctl->conn))
         return false;
 
+    if (vshCommandOptString(cmd, "mode", &mode) < 0) {
+        vshError(ctl, "%s", _("Invalid type"));
+        return false;
+    }
+
+    if (mode) {
+        if (STREQ(mode, "acpi")) {
+            flags |= VIR_DOMAIN_SHUTDOWN_ACPI_POWER_BTN;
+        } else if (STREQ(mode, "agent")) {
+            flags |= VIR_DOMAIN_SHUTDOWN_GUEST_AGENT;
+        } else {
+            vshError(ctl, _("Unknown mode %s value, expecting 'acpi' or 'agent'"), mode);
+            return false;
+        }
+    }
+
     if (!(dom = vshCommandOptDomain(ctl, cmd, &name)))
         return false;
 
-    if (virDomainReboot(dom, 0) == 0) {
+    if (virDomainReboot(dom, flags) == 0) {
         vshPrint(ctl, _("Domain %s is being rebooted\n"), name);
     } else {
         vshError(ctl, _("Failed to reboot domain %s"), name);
diff --git a/tools/virsh.pod b/tools/virsh.pod
index 67f93a9..72c6d8f 100644
--- a/tools/virsh.pod
+++ b/tools/virsh.pod
@@ -807,7 +807,7 @@ If I<--live> is specified, set scheduler information of a running guest.
 If I<--config> is specified, affect the next boot of a persistent guest.
 If I<--current> is specified, affect the current guest state.
 
-=item B<reboot> I<domain-id>
+=item B<reboot> I<domain-id> [I<--mode acpi|agent>]
 
 Reboot a domain.  This acts just as if the domain had the B<reboot>
 command run from the console.  The command returns as soon as it has
@@ -817,6 +817,10 @@ domain actually reboots.
 The exact behavior of a domain when it reboots is set by the
 I<on_reboot> parameter in the domain's XML definition.
 
+By default the hypervisor will try to pick a suitable shutdown
+method. To specify an alternative method, the I<--mode> parameter
+can specify C<acpi> or C<agent>.
+
 =item B<reset> I<domain-id>
 
 Reset a domain immediately without any guest shutdown. B<reset>
@@ -1190,7 +1194,7 @@ The I<--maximum> flag controls the maximum number of virtual cpus that can
 be hot-plugged the next time the domain is booted.  As such, it must only be
 used with the I<--config> flag, and not with the I<--live> flag.
 
-=item B<shutdown> I<domain-id>
+=item B<shutdown> I<domain-id> [I<--mode acpi|agent>]
 
 Gracefully shuts down a domain.  This coordinates with the domain OS
 to perform graceful shutdown, so there is no guarantee that it will
@@ -1205,6 +1209,10 @@ be lost once the guest stops running, but the snapshot contents still
 exist, and a new domain with the same name and UUID can restore the
 snapshot metadata with B<snapshot-create>.
 
+By default the hypervisor will try to pick a suitable shutdown
+method. To specify an alternative method, the I<--mode> parameter
+can specify C<acpi> or C<agent>.
+
 =item B<start> I<domain-name> [I<--console>] [I<--paused>] [I<--autodestroy>]
 [I<--bypass-cache>] [I<--force-boot>]
 
-- 
1.7.3.4




More information about the libvir-list mailing list