[PATCH] docs: add zpci information to pci-addresses.rst
Cornelia Huck
cohuck at redhat.com
Wed Apr 15 14:45:48 UTC 2020
On Wed, 15 Apr 2020 16:23:46 +0200
Boris Fiuczynski <fiuczy at linux.ibm.com> wrote:
> On 4/15/20 3:42 PM, Cornelia Huck wrote:
> > On Tue, 14 Apr 2020 23:06:47 +0200
> > Boris Fiuczynski <fiuczy at linux.ibm.com> wrote:
> >
> >> On 4/15/20 12:51 PM, Cornelia Huck wrote:
> >>> +In the simplest case, the following XML snippet
> >>> +
> >>> +::
> >>> +
> >>> + <controller type='pci' index='0' model='pci-root'/>
> >>> + <controller type='pci' index='1' model='pci-bridge'>
> >>> + <model name='pci-bridge'/>
> >>> + <target chassisNr='1'/>
> >>> + <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x0'>
> >>> + <zpci uid='0x0002' fid='0x00000001'/>
> >>> + </address>
> >>> + </controller>
> >>> + <interface type='bridge'>
> >>> + <mac address='02:ca:fe:fa:ce:04'/>
> >>> + <source bridge='virbr0'/>
> >>> + <model type='virtio'/>
> >>> + <address type='pci' domain='0x0000' bus='0x01' slot='0x01' function='0x0'>
> >>> + <zpci uid='0x0001' fid='0x00000000'/>
> >>> + </address>
> >>> + </interface>
> >>> +
> >>> +will result in the following in a Linux guest::
> >>> +
> >>> + 0001:00:00.0 Ethernet controller: Red Hat, Inc. Virtio network device
> >>> +
> >>> +Note that the PCI bridge is not visible in the guest; s390x always has a flat
> >>> +topology.
> >>> +
> >>> +Neither are any changes in the PCI address visible in the guest; replacing
> >>> +the PCI address for the virtio-net device with
> >>> +
> >>> +::
> >>> +
> >>> + <address type='pci' domain='0x0000' bus='0x01' slot='0x07' function='0x3'>
> >>> +
> >>> +will result in the exactly same view in the guest, as the addresses there
> >>> +are generated from the information provided via the ``zpci`` element (in
> >>> +fact, from the ``uid``).
> >>> +
> >> This explains that the uid is used by the guest to define the pci domain
> >> of the guest device.
> >> How about an addition for the fid? Something like:
> >>
> >> The function id 'fid' defines the slot address of the pci card in the
> >> guest. It can be observed in the guest at /sys/bus/pci/slots. In the
> >> example given above the card would be at /sys/bus/pci/slots/00000000.
> >
> > Hm, is it intentional that this does not show up in the actual pci
> > address? But maybe I'm confused.
> Are you referring to the slot of the pci address?
Yes.
>
> If yes, the pci slot does not provided the required address space for
> the function id. Also we once said that the pci bus in qemu would be
> like the pci bus of the CEC and the firmware does provide a a function
> id for every pci function. The zpci fid does one allow to do the same.
Ok, now I dimly remember something like that. Still confusing, but
makes sense.
>
> >
> >>
> >>
> >>> +Therefore, replacing the virtio-net device definition with the following XML
> >>> +snippet
> >>> +
> >>> +::
> >>> +
> >>> + <interface type='bridge'>
> >>> + <mac address='02:ca:fe:fa:ce:04'/>
> >>> + <source bridge='virbr0'/>
> >>> + <model type='virtio'/>
> >>> + <address type='pci' domain='0x0000' bus='0x01' slot='0x07' function='0x3'>
> >>> + <zpci uid='0x0007' fid='0x00000003'/>
> >>> + </address>
> >>> + </interface>
> >>> +
> >>> +will yield the following result in a Linux guest::
> >>> +
> >>> + 0007:00:00.0 Ethernet controller: Red Hat, Inc. Virtio network device
> >>>
> >> and the card would be at /sys/bus/pci/slots/00000003.
> >
> > Do you want to explain the fid/slot stuff in a patch on top? Despite
> > your attempts at time travel, this patch has already been pushed :)
> It seems to be a very pushy time... :( no matter how many breaks are
> produced... ;) 11 minutes from patch production time to commit time.
> Why even send it for review? :D
Well, I don't have commit rights O:-)
> Once I understand you confusion above I will provide a patch...
I'd say just go ahead.
More information about the libvir-list
mailing list