[Linux-cluster] cman_serviced crashed while rebooting two nodes

David Teigland teigland at redhat.com
Mon Mar 7 16:10:35 UTC 2005


On Fri, Mar 04, 2005 at 10:34:02AM +0100, Bastian Blank wrote:

> The other with the more serious:
> | Unable to handle kernel NULL pointer dereference at virtual address 0000000c
> |  printing eip:
> | c025f7fd
> | *pde = ma 00000000 pa 55555000
> |  [<c025f9b1>] cancel_uevents+0xd1/0x1d0
> |  [<c02eae88>] schedule+0x2c8/0x4b0
> |  [<c0260689>] process_lstart_done+0x9/0x30
> |  [<c0260755>] process_message+0xa5/0xc0
> |  [<c025d780>] serviced+0x0/0x180
> |  [<c0261fee>] process_nodechange+0x2e/0x60
> |  [<c025d8e3>] serviced+0x163/0x180
> |  [<c0127a04>] kthread+0x94/0xa0
> |  [<c0127970>] kthread+0x0/0xa0
> |  [<c0107241>] kernel_thread_helper+0x5/0x14
> | Oops: 0000 [#1]
> | CPU:    0
> | EIP:    0061:[<c025f7fd>]    Not tainted VLI
> | EFLAGS: 00010246   (2.6.10-xen-gfs-1) 
> | EIP is at cancel_one_uevent+0x48d/0x570

Thanks, this should be fixed in cvs.

-- 
Dave Teigland  <teigland at redhat.com>




More information about the Linux-cluster mailing list