[Linux-cluster] GFS problem

Pena, Francisco Javier francisco_javier.pena at roche.com
Fri Nov 24 14:18:25 UTC 2006


> Thank you for the response Francisco (or Francisco Javier? ^_^),

My full name is Francisco Javier :).

> no actually each switch is configured with a single zone including all
of the WWNs of HBAs and storage array ports, i'm going to zone it right
now if you > think that this is advisable. 
>
>But won't the node "sending the reset" affect the array ports (which
obviously MUST be in the same zone)?

Not really, the array ports are prepared for that. It is just that some
HBA do not like receiving those frames.

Javier




More information about the Linux-cluster mailing list