[Linux-cluster] Can't get past Segmentation Faults
isplist at logicore.net
isplist at logicore.net
Wed Jan 24 19:29:05 UTC 2007
Good point and that was indeed an issue. Some of the ports WERE blocked. All
have since been cleared.
Mike
On Wed, 24 Jan 2007 13:28:28 -0600, Jonathan E Brassow wrote:
> I would ensure that when the fencing occurred, that it didn't fence off
>
> the devices on the brocade switch. I would log into the brocade switch
> and ensure that all nodes are properly connected (and their ports are
> not disabled).
>
> brassow
>
> On Jan 24, 2007, at 11:39 AM, isplist at logicore.net wrote:
>
>> On Wed, 24 Jan 2007 11:15:28 -0600, Jonathan E Brassow wrote:
>>> are you using fibre channel fencing in your cluster?
>>>
>> Yes, Brocade switches with Xyratex chassis.
>>
>> Mike
>>
>>
>> --
>> Linux-cluster mailing list
>> Linux-cluster at redhat.com
>> https://www.redhat.com/mailman/listinfo/linux-cluster
More information about the Linux-cluster
mailing list