[Linux-cluster] clusvcadm Relocate <group> causing reboot.
Kaloyan Kovachev
kkovachev at varna.net
Wed Aug 3 11:47:37 UTC 2011
Hi,
post_join_delay is the wrong parameter to change. You will need to change
the 'shutdown_wait' or 'stop' timeout for the resource
On Wed, 03 Aug 2011 16:58:43 +0530, "jayesh.shinde"
<jayesh.shinde at netcore.co.in> wrote:
> Hi All ,
>
> I have query about the "clusvcadm" and "post_join_delay"
> I am using the high traffic Mail Server with "2 node active-active
> DRBD + RHCS." ( i.e node1 and node2)
>
> From node1 server when I try to relocate the group to other server ,
> the node1 get fence and get reboot and all services get shift to node2
> For relocating the service I am using following command :--
>
> clusvcadm -r imap2 -m node2
>
> I am not able to figure out why the node1 get fence and reboot while
> relocating. Some time the group relocation from one node to other
> happen smoothly. I have notice that without cluster when I run
> "/etc/init.d/cyrus-imapd stop" it takes long time. ( say 3 min). Its
> Because cyrus-imapd do the import export inside the local db files.
>
> in the cluster.conf I have below line
> <fence_daemon post_fail_delay="0" post_join_delay="3"/>
>
> If I change the post_join_delay="180" then will this help to solve my
> problem ?
>
> Is there any way to avoid rebooting while relocating group to another
> node , please suggest.
>
> Regards
> Jayesh Shinde
More information about the Linux-cluster
mailing list