[Linux-cluster] Handling of CPG_REASON_NODEDOWN in daemons

Vladislav Bogdanov bubble at hoster-ok.com
Wed Aug 17 15:13:11 UTC 2011


Hi all,

I hope I found a correct list.

I discovering a reason why node was not fenced on CPG_REASON_NODEDOWN event.

Here what I see in dlm_tool dump:
1313579105 Processing membership 80592
1313579105 Skipped active node 939787530: born-on=80580,
last-seen=80592, this-event=80592, last-event=80580
1313579105 Skipped active node 956564746: born-on=80564,
last-seen=80592, this-event=80592, last-event=80580
1313579105 del_configfs_node rmdir
"/sys/kernel/config/dlm/cluster/comms/1543767306"
1313579105 Removed inactive node 1543767306: born-on=80572,
last-seen=80580, this-event=80592, last-event=80580
1313579105 dlm:controld conf 2 0 1 memb 939787530 956564746 join left
1543767306
1313579105 dlm:ls:clvmd conf 2 0 1 memb 939787530 956564746 join left
1543767306
1313579105 clvmd add_change cg 4 remove nodeid 1543767306 reason 3
1313579105 clvmd add_change cg 4 counts member 2 joined 0 remove 1 failed 1
1313579105 clvmd stop_kernel cg 4
1313579105 write "0" to "/sys/kernel/dlm/clvmd/control"
1313579105 Node 1543767306/mgmt01 has not been shot yet
1313579105 clvmd check_fencing 1543767306 wait add 1313562825 fail
1313579105 last 0
1313579107 Node 1543767306/mgmt01 was last shot 'now'
1313579107 clvmd check_fencing 1543767306 done add 1313562825 fail
1313579105 last 1313579107
1313579107 clvmd check_fencing done

That means that dlm_controld received CPG_REASON_NODEDOWN event for
clvmd CPG and did not call kick_node_from_cluster(), so pacemaker didn't
do fencing on behalf of clvmd cpg.

Please correct me if I'm wrong:
* Request for fencing of node on CPG_REASON_NODEDOWN event was
historically left to groupd to do.
* That's why all daemons (fenced, dlm_controld, gfs2_controld) call
kick_node_from_cluster() only on CPG_REASON_PROCDOWN event, not on
CPG_REASON_NODEDOWN.
* groupd is obsoleted in 3.x.

Shouldn't daemons request fencing on CPG_REASON_NODEDOWN too?
Now they only mark node as failed and increase cg failcount.

I use pacemaker-based setup, and actually use only (obsoleted)
dlm_controld.pcmk, but problems seems to be a little bit wider than that
daemons one.

Setup is:
corosync-1.4.1
openais-1.1.4
pacemaker-tip
clusterlib-3.1.1
dlm_controld.pcmk from 3.0.17
lvm2-cluster-2.0.85

Best,
Vladislav