[Linux-cluster] Freeze with cmirror and cLVM
nagius at astek.fr
nagius at astek.fr
Mon Dec 19 16:06:13 UTC 2011
Hello all,
We've got a problem using a mirrored and clustered LV within a 5 nodes
cluster.
Everything is fine, except when a node leave the cluster, with
cman_tool leave, /etc/init/d/cman stop, electric poweroff or whatever.
In this case the storage just freeze on the others nodes, during 20
seconds, until openais take into account the configuration change.
We can see this during the freeze in /var/log/messages :
openais[3136]: [TOTEM] The token was lost in the OPERATIONAL state.
[...]
kernel: device-mapper: dm-log-clustered: [1lXq0Alc] Request timed
out: [DM_CLOG_MARK_REGION/405288] - retrying
[...]
openais[3136]: [TOTEM] entering OPERATIONAL state.
I'm running lastest 5.7, with :
- kernel-xen-2.6.18-274.12.1,
- cman-2.0.115-85,
- lvm2-cluster-2.02.84-6
- cmirror-1.1.39-10
- kmod-cmirror-xen-0.1.22-3
Is this a normal behavior ?
Thanks for help
Nicolas AGIUS
----------------------------------------------------------------
This message was sent using IMP, the Internet Messaging Program.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/linux-cluster/attachments/20111219/0d4c9823/attachment.htm>
More information about the Linux-cluster
mailing list