[Linux-cluster] Replacing network switch in a cluster
Martijn Storck
martijn.storck at gmail.com
Fri Jun 17 07:26:47 UTC 2011
Hi all,
Unfortunately I have to swap out the switch that is used for the cluster
traffic of our 4-node cluster for a new one. I'm hoping I can do this by
connecting the new switch to the old switch and then moving the nodes over
one by one.
Can I change the cluster configuration so that there is a longer grace
period before a node is deemed 'lost' and gets fenced? The only line in my
cluster.conf that looks like it has anything to do with it is this one:
<totem consensus="4800" join="60" token="10000"
token_retransmits_before_loss_const="20"/>
I think that with faststart enabled the link with a node will be down for
only a few seconds. I realize that this probably means the cluster will lock
up during that period (since we use a lot of GFS), but it's still better
than having to bring the entire cluster down.
Kind regards,
Martijn Storck
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/linux-cluster/attachments/20110617/86cc4e9e/attachment.htm>