[linux-lvm] lv with cmirror

Michael Eisenkölbl / FIS michael.eisenkoelbl at cargo-partner.com
Fri Jul 6 04:55:05 UTC 2007


Hi,

I installed a clustered VG with a mirrored LV (RHEL4.5 and cmirror).
and using three iscsi storages (each two channels) and multipathd ... to 
be sure.

If I disconnect one iscsi storage, the LV is not working.
the command lvs or lvdisplay stucks.... when connecting again, the 
command will be
finished and everything will work.

why doesn't it remove the fault pv? any ideas?

kind regards,
michael




More information about the linux-lvm mailing list