[sos-devel] [PATCH] [iprconfig] add plugin for IBM Power RAID adapters

Vasant Hegde hegdevasant at linux.vnet.ibm.com
Tue Jan 27 07:41:49 UTC 2015


On 12/16/2014 01:03 PM, Aruna Balakrishnaiah wrote:
> 
> Bryn,
> 
> Tested. Works fine, you can merge.

Bryn,

Did you merge this one ? I don't see this in upstream
sos..(https://github.com/sosreport/sos)



-Vasant

> 
> Regards,
> Aruna
> 
> On Monday 15 December 2014 11:04 PM, Bryn M. Reeves wrote:
>> Capture information which helps in better understanding of
>> IBM Power RAID storage adapter configuration. Since iprconfig
>> is specific to power adding the relevant commands in powerpc plugin.
>>
>> Signed-off-by: Aruna Balakrishnaiah <aruna at linux.vnet.ibm.com>
>> Signed-off-by: Bryn M. Reeves <bmr at redhat.com>
>> ---
>>   sos/plugins/iprconfig.py | 110 +++++++++++++++++++++++++++++++++++++++++++++++
>>   1 file changed, 110 insertions(+)
>>   create mode 100644 sos/plugins/iprconfig.py
>>
>> diff --git a/sos/plugins/iprconfig.py b/sos/plugins/iprconfig.py
>> new file mode 100644
>> index 0000000..b77c192
>> --- /dev/null
>> +++ b/sos/plugins/iprconfig.py
>> @@ -0,0 +1,110 @@
>> +# This program is free software; you can redistribute it and/or modify
>> +# it under the terms of the GNU General Public License as published by
>> +# the Free Software Foundation; either version 2 of the License, or
>> +# (at your option) any later version.
>> +
>> +# This program is distributed in the hope that it will be useful,
>> +# but WITHOUT ANY WARRANTY; without even the implied warranty of
>> +# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
>> +# GNU General Public License for more details.
>> +
>> +# You should have received a copy of the GNU General Public License
>> +# along with this program; if not, write to the Free Software
>> +# Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA.
>> +
>> +# This plugin enables collection of logs for Power systems
>> +
>> +import os
>> +import re
>> +from sos.plugins import Plugin, RedHatPlugin, UbuntuPlugin, DebianPlugin
>> +from sos.utilities import is_executable
>> +
>> +
>> +class IprConfig(Plugin, RedHatPlugin, UbuntuPlugin, DebianPlugin):
>> +    """IBM Power RAID storage adapter configuration information
>> +    """
>> +
>> +    plugin_name = 'iprconfig'
>> +
>> +    def check_enabled(self):
>> +        arch = self.policy().get_arch()
>> +        return arch == "ppc64" and is_executable("iprconfig")
>> +
>> +    def setup(self):
>> +        self.add_cmd_output([
>> +            "iprconfig -c show-config",
>> +            "iprconfig -c show-alt-config",
>> +            "iprconfig -c show-arrays",
>> +            "iprconfig -c show-jbod-disks",
>> +            "iprconfig -c show-ioas",
>> +        ])
>> +
>> +        show_ioas = self.call_ext_prog("iprconfig -c show-ioas")
>> +        if not show_ioas['status'] == 0:
>> +            return
>> +
>> +        devices = []
>> +        if show_ioas['output']:
>> +            p = re.compile('sg')
>> +            for line in show_ioas['output'].splitlines():
>> +                temp = line.split(' ')
>> +                # temp[0] holds the device name
>> +                if p.search(temp[0]):
>> +                    devices.append(temp[0])
>> +
>> +        for device in devices:
>> +            self.add_cmd_output("iprconfig -c show-details %s" % (device,))
>> +
>> +        # Look for IBM Power RAID enclosures (iprconfig lists them)
>> +        show_config = self.call_ext_prog("iprconfig -c show-config")
>> +        if not show_config['status'] == 0:
>> +            return
>> +
>> +        if not show_config['output']:
>> +            return
>> +
>> +# iprconfig -c show-config
>> +# Name   PCI/SCSI Location         Description               Status
>> +# ------ ------------------------- ------------------------- -----------------
>> +#        0005:60:00.0/0:            PCI-E SAS RAID Adapter    Operational
>> +# sda    0005:60:00.0/0:0:0:0       Physical Disk             Active
>> +# sdb    0005:60:00.0/0:1:0:0       Physical Disk             Active
>> +# sdc    0005:60:00.0/0:2:0:0       Physical Disk             Active
>> +# sdd    0005:60:00.0/0:3:0:0       Physical Disk             Active
>> +# sde    0005:60:00.0/0:4:0:0       Physical Disk             Active
>> +# sdf    0005:60:00.0/0:5:0:0       Physical Disk             Active
>> +#        0005:60:00.0/0:8:0:0       Enclosure                 Active
>> +#        0005:60:00.0/0:8:1:0       Enclosure                 Active
>> +
>> +        show_alt_config = "iprconfig -c show-alt-config"
>> +        altconfig = self.call_ext_prog(show_alt_config)
>> +        if not (altconfig['status'] == 0):
>> +            return
>> +
>> +        if not altconfig['output']:
>> +            return
>> +
>> +# iprconfig -c show-alt-config
>> +# Name   Resource Path/Address      Vendor   Product ID       Status
>> +# ------ -------------------------- -------- ---------------- -----------------
>> +# sg9    0:                         IBM      57C7001SISIOA    Operational
>> +# sg0    0:0:0:0                    IBM      MBF2300RC        Active
>> +# sg1    0:1:0:0                    IBM      MBF2300RC        Active
>> +# sg2    0:2:0:0                    IBM      HUC106030CSS600  Active
>> +# sg3    0:3:0:0                    IBM      HUC106030CSS600  Active
>> +# sg4    0:4:0:0                    IBM      HUC106030CSS600  Active
>> +# sg5    0:5:0:0                    IBM      HUC106030CSS600  Active
>> +# sg7    0:8:0:0                    IBM      VSBPD6E4A  3GSAS Active
>> +# sg8    0:8:1:0                    IBM      VSBPD6E4B  3GSAS Active
>> +
>> +        for line in show_config['output'].splitlines():
>> +            if "Enclosure" in line:
>> +                temp = re.split('\s+', line)
>> +                # temp[1] holds the PCI/SCSI location
>> +                pci, scsi = temp[1].split('/')
>> +                for line in altconfig['output'].splitlines():
>> +                    if scsi in line:
>> +                        temp = line.split(' ')
>> +                        # temp[0] holds device name
>> +                        self.add_cmd_output("iprconfig -c "
>> +                                            "query-ses-mode %s" % (temp[0],))
> 
> _______________________________________________
> sos-devel mailing list
> sos-devel at redhat.com
> https://www.redhat.com/mailman/listinfo/sos-devel
> 




More information about the sos-devel mailing list