[vfio-users] PLX switch report a UR when EP tries to DMA to VM's memory

Alex Williamson alex.williamson at redhat.com
Fri Sep 14 03:03:25 UTC 2018


On Thu, 13 Sep 2018 20:55:39 -0600
Alex Williamson <alex.williamson at redhat.com> wrote:

> On Fri, 14 Sep 2018 01:25:20 +0000
> "Wuzongyong (Euler Dept)" <cordius.wu at huawei.com> wrote:
> 
> > > > Hi,
> > > >
> > > > I notice a problem with a PCIe endpoint, which is behind a PLX switch,    
> > > assigned to a VM by VFIO.    
> > > > The problem is switch report a UR error when the EP tries to DMA to a    
> > > memory zone inside VM's address space.    
> > > > Assume that the DMA destination address is between in the VM's ram
> > > > address space, and unfortunately that address value in host's point of    
> > > view just hit the PLX switch  upstream port BAR0 memory-mapped IO range.    
> > > > In a result, the DMA will failed because SW think this memory request
> > > > is invalid if the destination address hit its UP's bar.
> > > > Is this a hardware bug or qemu/seabios doesn't maintain a proper address    
> > > space for VM?
> > > 
> > > Upstream switch ports are generally single function devices and therefore
> > > governed by 6.12.1.3 (PCIe base spec rev 4.0, v1) which indicates an ACS
> > > capability must not be implemented.  We can therefore read into section
> > > 6.12.2 on interoperability which indicates the interaction between ACS and
> > > non-ACS components, including:
> > > 
> > >  * When ACS P2P Request Redirect, ACS P2P Completion Redirect, or both
> > >    are being used, certain components in the PCI Express hierarchy must
> > >    support ACS Upstream Forwarding (of Upstream redirected Requests).
> > >    Specifically:
> > >    ...
> > >    Between each ACS component where P2P TLP redirection is enabled and
> > >    its associated Root Port, any intermediate Switches must support ACS
> > >    Upstream Forwarding. Otherwise, how such Switches handle Upstream
> > >    redirected TLPs is undefined.
> > > 
> > > It's my interpretation therefore that in a configuration where the switch
> > > downstream ports supports ACS, the switch upstream port must implicitly
> > > support upstream forwarding, thus I would consider this a hardware issue.
> > > The alternative is that we need to poke holes in the VM address space to
> > > account for any possible conflict and assigned device hot-add becomes
> > > nearly a non-starter.  Thanks,
> > > 
> > > Alex    
> > 
> > Thanks for your explanation.
> > Do you know are there other vendors' switches that wouldn't result in this problem?  
> 
> I've generally thought PLX switches were good, I know the NVIDIA GRID
> cards made use of them and perhaps the multi-GPU Tesla cards still do.
> PLX makes a large variety of switches though, so they could be a
> different family, but also the nature of this issue can mask the
> problem if the address spaces don't overlap in a way that triggers it.

I should have asked previously, does the PLX switch in question support
ACS on the downstream ports and is it enabled?  Thanks,

Alex