[Linux-cluster] 2-node cluster and fence_drac

hai wu haiwu.us at gmail.com
Wed Aug 9 20:39:50 UTC 2006


I got the following errors after "reboot -fn" on erd-tt-eproof1, which
script do I need to change?

Aug  9 15:35:40 erd-tt-eproof2 kernel: CMAN: removing node erd-tt-eproof1
from t
he cluster : Missed too many heartbeats
Aug  9 15:35:40 erd-tt-eproof2 fenced[3437]: erd-tt-eproof1 not a cluster
member
 after 0 sec post_fail_delay
Aug  9 15:35:40 erd-tt-eproof2 fenced[3437]: fencing node "erd-tt-eproof1"
Aug  9 15:35:42 erd-tt-eproof2 fenced[3437]: agent "fence_drac" reports:
WARNING
: unable to detect DRAC version ' Dell Embedded Remote Access Controller
(ERA) F
irmware Version 3.31 (Build 07.15) ' WARNING: unsupported DRAC version
'__unknow
n__' failed: unable to determine power state

This is DRAC on Dell PE2650.
Thanks,
Hai

On 8/9/06, Lon Hohberger <lhh at redhat.com> wrote:
>
> On Wed, 2006-08-09 at 13:44 -0500, hai wu wrote:
> > Thanks Lon. We got redundant power here.
> >
> > How can I test this fence_drac? How to simulate a failure on one node
> > and know for sure that it does kick in and restarts the failed node in
> > the cluster?
>
> After both nodes join the cluster, try doing 'reboot -fn' on the node.
>
> Oh, also, you should be booting with acpi=off when using integrated
> power management.
>
> -- Lon
>
>
>
> --
> Linux-cluster mailing list
> Linux-cluster at redhat.com
> https://www.redhat.com/mailman/listinfo/linux-cluster
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/linux-cluster/attachments/20060809/d65d70a7/attachment.htm>


More information about the Linux-cluster mailing list