[Linux-cluster] Conga issue

Scott Becker scottb at bxwa.com
Mon Nov 12 17:47:16 UTC 2007


I use luci to configure the main fencing method and afterwards, luci 
show's me extra entries. I have two power switches (apc 7920s) one for 
each power feed and to each power supply in each node. Currently my 
cluster.conf contains this:

for node 2:
<fence>
 <method name="1">
  <device name="RackPDU1" option="off" port="2"/>
  <device name="RackPDU2" option="off" port="2"/>
 </method>
</fence>

for node 3:
<fence>
 <method name="1">
  <device name="RackPDU1" option="off" port="3"/>
  <device name="RackPDU2" option="off" port="3"/>
  <device name="RackPDU1" option="on" port="3"/>
  <device name="RackPDU2" option="on" port="3"/>
 </method>
</fence>



When I view the config in luci, for node 2 it show exactly what I 
entered but for node 3 it shows 4 entries instead of the two I entered, 
without any indication of option="off" vs option="on".

Luci at one point even show 4 entries under main fence method and the 
same 4 entries under backup fence method even though I never set any there.

Luci (or ricci) has a problem which needs fixed but my first question is 
what should be in cluster.conf? Is the option="on" needed?


    thanks
    scottb




More information about the Linux-cluster mailing list