[Linux-cluster] fencing issue - with attach logs&conf

brem belguebli brem.belguebli at gmail.com
Wed Mar 3 13:25:44 UTC 2010


Exactly.

2010/3/3 שלום קלמר <sklemer at gmail.com>:
> Hi.
>
> I got 2 power supplies. But if someone by mistake pull the power cables , is
> that mean
>
> That the services will not failover ??
>
> Regards
>
> Shalom.
>
> On Wed, Mar 3, 2010 at 1:15 AM, Georgi Stanojevski <glisha at gmail.com> wrote:
>>
>> On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <sklemer at gmail.com> wrote:
>>
>>>
>>> The only test which failed was - pulling out power cable from one node.
>>>
>>> The other system try in loop fencing the failed node & services not
>>> relocated.
>>>
>>
>> As I understand this is by design.
>>
>> When you pull out the power cables you shutdown the fencing device on that
>> node and the remaining node can't successfully fence it.
>>
>> The nodes should have redundant power supplies, to avoid single point of
>> failure.
>>
>> --
>> Glisha
>> http://
>>
>> --
>> Linux-cluster mailing list
>> Linux-cluster at redhat.com
>> https://www.redhat.com/mailman/listinfo/linux-cluster
>
>
> --
> Linux-cluster mailing list
> Linux-cluster at redhat.com
> https://www.redhat.com/mailman/listinfo/linux-cluster
>




More information about the Linux-cluster mailing list