Hi.
I got 2 power supplies. But if someone by mistake pull the power cables , is
that mean
That the services will not failover ??
Regards
Shalom.
On Wed, Mar 3, 2010 at 1:15 AM, Georgi Stanojevski <glisha at gmail.com> wrote:
> On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <sklemer at gmail.com> wrote:
>
>>
>> The only test which failed was - pulling out power cable from one node.
>>
>> The other system try in loop fencing the failed node & services not
>> relocated.
>>
>>
>>
> As I understand this is by design.
>
> When you pull out the power cables you shutdown the fencing device on that
> node and the remaining node can't successfully fence it.
>
> The nodes should have redundant power supplies, to avoid single point of
> failure.
>
> --
> Glisha
> http://
>
> --
> Linux-cluster mailing list
> Linux-cluster at redhat.com
> https://www.redhat.com/mailman/listinfo/linux-cluster
>