On 07/02/14 11:13 AM, Benjamin Budts wrote:
> Gents,

We're not all gents. ;)

> I have a 2 node setup (with quorum disk), redhat 6.5 & a luci mgmt console.
>
> Everything has been configured and we’re doing failover tests now.
>
> Couple of questions I have :
>
> ·When I simulate a complete power failure of a servers pdu’s (no more
> access to idrac fencing or APC PDU fencing) I can see that the fencing
> of that node who was running the application fails ßI  noticed unless
> fencing returns an OK I’m stuck and my application won’t start on my
> 2^nd node. Which is ok I guess, because no fencing could mean there is
> still I/O on my san.

This is expected. If a lost node can't be put into a known state, there 
is no safe way to proceed. To do so would be to risk a split brain at 
least, and data loss/corruption at worst.

The way I deal with this is to have nodes with redundant power supplies 
and use two PDUs and two UPSes. This way, the failure of on cirtcuit / 
UPS / PDU doesn't knock out the power to the mainboard of the nodes, so 
you don't lose IPMI.

> Clustat also shows on the active node that the 1^st node is still
> running the application.

That's likely because rgmanager uses DLM, and DLM blocks until the fence 
succeeds, so it can't update it's view.

> How can I intervene manually, so as to force a start of the application
> on the node that is still alive ?

If you are *100% ABSOLUTELY SURE* that the lost node has been powered 
off, then you can run 'fence_ack_manual'. Please be super careful about 
this though. If you do this, in the heat of the moment with clients or 
bosses yelling at you, and the peer isn't really off (ie: it's only 
hung), you risk serious problems.

I can not emphasis strongly enough the caution needed when using this 
command.

> Is there a way to tell the cluster, don’t take into account node 1
> anymore and don’t try to fence anymore, just start the application on
> the node that is still ok ?

No. That would risk a split brain and data corruption. The only safe 
option for the cluster, if the face of a failed fence, is to hang. As 
bad as it is to hang, it's better than risking corruption.

> I can’t possibly wait until power returns to that server. Downtime could
> be too long.

See the solution I mentioned earlier.

> ·If I tell a node to leave the cluster in Luci, I would like it to
> remain a non-cluster member after the reboot of that node. It rejoins
> the cluster automatically after a reboot. Any way to prevent this ?
>
> Thx

Don't let cman and rgmanager start on boot. This is always my policy. If 
a node failed and got fenced, I want it to reboot, so that I can log 
into it and figure out what happened, but I do _not_ want it back in the 
cluster until I've determined it is healthy.

hth

-- 
Digimer
Papers and Projects: https://alteeve.ca/w/