[Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

Marek Grac mgrac at redhat.com
Fri Apr 29 08:08:10 UTC 2011


Hi,

On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
> Hi all,
>
> I am using RHCS on IBM bladecenter with blade center fencing. I 
> plugged out a blade from blade center chassis slot and was hoping that 
> failover to occur. However when I did so, I get following message -
>
> fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to 
> obtain correct plug status or plug is not available
> fenced[10240]: fence "blade1" failed
>
> Is this supported that if I plug out blade from its slot, then 
> failover occur without manual intervention? If so, which fencing must 
> I use?

You can use option missing_as_off (or --missing-as-off at command line) 
which returns off even in a case when blade does not exists.

m,



More information about the Linux-cluster mailing list