Hi,
On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
> Hi all,
>
> I am using RHCS on IBM bladecenter with blade center fencing. I
> plugged out a blade from blade center chassis slot and was hoping that
> failover to occur. However when I did so, I get following message -
>
> fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to
> obtain correct plug status or plug is not available
> fenced[10240]: fence "blade1" failed
>
> Is this supported that if I plug out blade from its slot, then
> failover occur without manual intervention? If so, which fencing must
> I use?
You can use option missing_as_off (or --missing-as-off at command line)
which returns off even in a case when blade does not exists.
m,