[Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed
Parvez Shaikh
parvez.h.shaikh at gmail.com
Fri Apr 29 08:15:03 UTC 2011
Hi Marek,
Can we give this option in cluster.conf file for bladecenter fencing device
or method
For IPMI, fencing is there similar option?
On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac <mgrac at redhat.com> wrote:
> Hi,
>
>
> On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
>
>> Hi all,
>>
>> I am using RHCS on IBM bladecenter with blade center fencing. I plugged
>> out a blade from blade center chassis slot and was hoping that failover to
>> occur. However when I did so, I get following message -
>>
>> fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain
>> correct plug status or plug is not available
>> fenced[10240]: fence "blade1" failed
>>
>> Is this supported that if I plug out blade from its slot, then failover
>> occur without manual intervention? If so, which fencing must I use?
>>
>
> You can use option missing_as_off (or --missing-as-off at command line)
> which returns off even in a case when blade does not exists.
>
> m,
> --
> Linux-cluster mailing list
> Linux-cluster at redhat.com
> https://www.redhat.com/mailman/listinfo/linux-cluster
>